Intermatic PE1501RC Скачать руководство пользователя страница 45

Eight: Warranty     

4

Providing a brighter solution.™

Section 8: 

 

Warranty

ONE YEAR LIMITED WARRANTY

If, within one (1) year from the date of purchase, this product fails due to defect in material or workmanship, Intermatic Incorporated will repair 

or replace it, as its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This 

warranty does not apply to: (a) damage to units caused by accident, dropping, or abuse in handling, acts of God, or any negligent use; (b) units 

which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) 

damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LEDs, and batteries; (f) the finish on any portion of the product, 

such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or 

reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE 

EXCLUSION OR LIMITATION OF INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY 

IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY 

AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED 

WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATE ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS 

ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, 

along with proof of purchase, postage prepaid, to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/

After Sales Service/7777 Winn Rd., Spring Grove, IL 60081-7000 <http://intermatic.com>. Please be sure to wrap the product securely to avoid 

shipping damage.

Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, 

in the specifications and material contained herein, and shall not be responsible for any damages, direct or consequential, caused by reliance on 

the material presented.

WARRANTY REGISTRATION

Owner’s Name___________________________________     Signature_____________________________________________

Street Address__________________________________________     Date of Purchase ______________________________

City__________________________________     State_____     Zip ______________     Phone _________________________ 

Authorized Dealer ________________________________________     Sales Rep ___________________________________

City__________________________________     State_____     Zip ______________     Phone _________________________

How did you hear about our product? (Please check all that apply.)

___Pool Store Employee     ___Pool Builder     ___Pool Service     ___Direct Mail Ad     ___In-Store Display     

___Friend/Relative     ___Magazine     ___Newspaper     ___Radio     ___TV     ___Catalog     ___Other: ___________

To activate your warranty, please return this portion to:

 

 

 

 

 

Intermatic, Inc.

 

 

 

 

 

7777 Winn Road

 

 

 

 

 

Spring Grove, IL 60081

 

 

 

 

 

or by FAX: 815-675-7055

Содержание PE1501RC

Страница 1: ...PE1541RC PE1501RC Installation and User Guide Pool Spa Combination Systems Pool Systems Spa Systems Wave PE4 Series Mini Wave...

Страница 2: ...owning WARNING To Reduce the Risk of Injury The water in a spa should never exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water t...

Страница 3: ...such as a light telephone radio or television within 5 feet 1 5m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Wat...

Страница 4: ...10 For Non Booster Pump Pool Cleaner Installations 11 Section 3 Control Center Installation 12 Mounting the Control Center 12 Wiring the System Power 12 Bonding the Control Center 13 Wiring the Indiv...

Страница 5: ...0 Installing the 35 ft Antenna Extension Cable PA121 31 Installing and Configuring Optional Repeaters 31 Everyday Use of the Hand Held Controller 33 Changing between Pool and Spa 33 Setting Pool and S...

Страница 6: ...onfiguration or system as indicated Removable antenna PA118 can be ordered separately Hand Held Transceiver PE950 Up to 5 units can be used with an Mini Wave system Additional units can be ordered sep...

Страница 7: ...es for pool spa combos Adjustable cam rotates diverter valves to multiple degree settings Designed to operate most 2 way and 3 way diverter valves Shipping Weight 3 lbs 1 4 kg Agency Approval CSA C US...

Страница 8: ...e control center is successful The Mini Wave includes this antenna extension cable assembly OMRON Relay w 24VDC Coil 2 pin Connector 143T145A There are four OMRON Relay Assemblies 143T135A in the Mini...

Страница 9: ...al obstacles like brick walls or structures However by plugging in a Transceiver Repeater Module where necessary long distances or physical obstructions can be overcome Steel Outdoor Enclosure Suitabl...

Страница 10: ...iagrams will not apply For Pool and Spa Combo Installations For Booster Pump Pool Cleaner Installations Pool Spa Filter Check Valve Spa Make up Filter Pump Intake Return Return Intake Skimmers Heater...

Страница 11: ...olution For Non Booster Pump Pool Cleaner Installations Pool Spa Filter Check Valve Spa Make up Filter Pump Intake Return Return Intake Heater Energy Filter Pool Spa Filter Check Valve Spa Make up Fil...

Страница 12: ...ch circuit protection installed at the Main Power Panel Wiring the System Power Run wire from the Main Power Panel to your Control Center and connect the leads to the Control Center Breaker Base See d...

Страница 13: ...t depending on the version with up to eight ON OFF settings Equipment that requires programmed ON OFF times is already wired to the first or second relay i e filter pumps booster pumps etc On demand e...

Страница 14: ...C Blower 120 VAC Jet Pump 240 VAC Filter Pump Relay Blower Relay Optional Relay Aux Relay Jet Pump Relay Line 1 Load 1 Line 2 Load 2 Primary NEUTRAL Filter Pump 240 VAC Blower 120 VAC Jet Pump 240 VAC...

Страница 15: ...ng the neutral wire from the secondary of the transformer to the 12VAC light See Figure 3 6 Connect the hot black as follows from the LOAD side of the GFCI to the line side of the appropriate relay Se...

Страница 16: ...the temp sensor Only an Intermatic Sensor will work with this controller Follow the directions below to install and mount your water temperature sensor Drill a 3 8 hole in the pipe between the filter...

Страница 17: ...ase the P S button located on the Membrane pad to illuminate the green light beside the P S button This indicates that the control and actuators are in the SPA mode Use the switch located on your moto...

Страница 18: ...wo wire one function configuration Raypak heater Connect two 14 gauge wires designed for use in hot environments to the two brown wires on the panel mounted receiver Connect one end of either 14 gauge...

Страница 19: ...in hot environments to the two brown wires marked heater connection on the panel mounted receiver in the Mini Wave Control Center and attach the other end to the two black wires on the heater See Figu...

Страница 20: ...ire connect the black wires to each yellow wire See Figure 3 20 Route the wires out through the knockout on the bottom of the Control Box Do not disconnect high limit or pressure switches Turn the hea...

Страница 21: ...d the CLOCK button Press the HOUR button to advance the clock to the correct hour of the day Repeat with the MIN button NOTE Take care to observe correct AM and PM settings Release the CLOCK button wh...

Страница 22: ...word ON to immediately power Relay 1 ON OFF to immediately power Relay 1 OFF The clock will continue to operate in Manual Mode until you change the clock to Timer Mode Changing the Clock Battery The f...

Страница 23: ...use a failure of the pool or spa equipment Remove the Low Voltage Divider to gain access to the Relay Screws See Figure 5 1 Remove the filler plate on the Low Voltage Divider by bending the plate back...

Страница 24: ...ramming section if special programming is required Depending on the configuration above Button 3 will now control this feature Some examples of this feature are Cleaner Pump and Actuator combination W...

Страница 25: ...ess Plate from the second timer hole on the Deadfront Cover See Figure 5 6 Remove the Low Voltage Divider to gain access to the Control Chassis Screws See Figure 5 7 Remove the screws that secure the...

Страница 26: ...rminals labeled Ext Timer located on the lower Control Board NOTE This connection is a dry contact connection Any voltage supplied to these two connectors will damage the control board and void the wa...

Страница 27: ...mends a five minute cool down time for the heat exchanger Program an OFF time on the Fireman s Switch Timer that is five minutes less than the OFF time programmed on the Pump Timer This will ensure th...

Страница 28: ...sists contact Intermatic Customer Service Press any button on the Hand Held Remote to wake it from sleep The unit goes to sleep to conserve battery life when it has been idle for 60 seconds The screen...

Страница 29: ...d CHLR buttons at the same time for about 5 seconds This will put the device in programming mode as shown at the right NOTE If you pause in the programming procedure for 30 seconds or so the screen au...

Страница 30: ...king around the yard with the Hand Held Remote and look on the screen to see if there are any areas where STAT OK changes to STAT which means the Hand Held and the Control Center are no longer communi...

Страница 31: ...Control Center NOTE The relay between Repeaters and the rest of the system causes a delay in response time Wait a few seconds for commands you enter on the Hand Held Remote to register Plug a Transcei...

Страница 32: ...peater is now part of the network You can add more repeaters as necessary REMEMBER When you have one or more repeaters installed in a network you increase the response time the time between when you p...

Страница 33: ...nged to Spa and the temperature shown is the water temperature of the Spa NOTE The large temperature display shown on the Hand Held Remote Screen reflects the current water temperature of the Pool or...

Страница 34: ...rols the Valve Actuators operating the booster pump a water feature or whatever else you might have installed Button P S controls the Valve Actuators When you press any of these buttons the appropriat...

Страница 35: ...RIMARY controller must be replaced due to loss damage etc you must reprogram from scratch to create a new PRIMARY controller then reprogram any additional controllers as SECONDARY controllers Press an...

Страница 36: ...he same time for about 5 seconds This will put the device in programming mode as shown at the right Press the 5 button to select MORE OPTIONS A new screen will appear as shown at the right Press the 1...

Страница 37: ...or these different variables It s best to adjust this value while standing close to the panel to ensure good communication between the Hand Held Remote and Panel Mount Receiver Press and release any b...

Страница 38: ...correct time of day Verify that power is ON to the panel Turn the main circuit breaker that feeds the panel to the ON position Use a voltmeter to verify that voltage is present at the buss terminals...

Страница 39: ...t is closing when turned ON Below the Load and Line terminals of each relay is a black boss that indicates the state of the relay Turn ON Circuit 1 and verify that the black boss on the 1 relay is rec...

Страница 40: ...gaged in the valve it controls Tighten the screw located on the top of the actuator Turn the valve handle until actuator engages If the actuator IS NOT engaged the handle will turn and then engage If...

Страница 41: ...A batteries Make sure the batteries are installed and are properly aligned according to the polarity markings in the battery compartment Do not mix fully charged batteries with partially charged batte...

Страница 42: ...6 7 8 Verify that filter pump is turned ON and running Turn ON the circuit that controls the filter pump Verify that the filter pump is running and that there is adequate flow through the heater Verif...

Страница 43: ...he area the Hand Held Transceiver lost communication Install a Transceiver Repeater Module HA04C in this outlet and program the Repeater Module by following the instructions on page 31 See page 9 for...

Страница 44: ...n the spa position Push the P S button on the Hand Held Remote Transceiver to change the valves back to the pool position Push button 3 to turn on the cleaner pump The cleaner pump should now come ON...

Страница 45: ...THE DURATION OF AN IMPLIED WARRANTY SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or...

Страница 46: ..._____________________________________________________________________________________________ ________________________________________________________________________________________________ _________...

Страница 47: ..._____________________________________________________________________________ ________________________________________________________________________________________________ _________________________...

Страница 48: ...c Inc 7777 Winn Road Spring Grove Illinois 60081 9698 www intermatic com Intermatic Customer Service 815 675 7000 8 a m through 4 30 p m CT Monday through Friday 2007 Intermatic Inc Printed in U S A 1...

Отзывы: