1
Mini-Wave PE4 Installation Guide
Copyright © 2006 Intermatic, Inc.
Fireman Switch Connection
The Mini-Wave Control System is capable of
controlling most heaters or heat pumps in the
market today, using thermostatic circuitry of 24VAC
@ 2A or less. Locate your heater on the following
pages and follow the instructions for proper
installation with your Mini-Wave Control Center.
NOTE:
Your Mini-Wave Control System can be
modified to provide a cool-down period for your
heater. Consult your heater owner’s manual for
specifics concerning a cool-down period
requirement.
Connection for Teledyne Laars Heater
Connect two #14 gauge wires, designed for use
in hot environments, to the two brown wires,
marked heater connection, on the panel mount
receiver.
Connect the other ends of the #14 gauge wires
from Step 1 to the Fireman’s Switch terminal bar
in place of the factory installed wire loop.
Do not disconnect high limit or pressure
switches.
Turn the heater thermostat(s) to maximum
setting.
Turn the heater switch to the ON position.
For dual thermostat heaters turn switch to Spa
position.
Connection for Raypak Heaters
The following connection procedure is for the
two wire-one function configuration Raypak
heater.
Connect two #14 gauge wires, designed for
use in hot environments, to the two brown
wires on the panel-mounted receiver.
Connect one end of either #14 gauge wires
from Step 1 to both the orange/black and
black/orange wires on the Raypak heater.
Connect the remaining #14 gauge wire
from Step 1 to the yellow/black wire on the
Raypak heater.
1.
2.
3.
4.
5.
1.
2.
3.
Water Temp Wires
(Black/White)
Fireman’s Switch
Wires
(Brown/Brown)
Wires from
Water Temp Sensor
(Black/White)
Make connection
with connectors
provided
Fireman’s Switch
Wires from Heater
Cable to Bottom
PC Board
Cable to Top
PC Board
Water Temp Wires
(Black/White)
Fireman’s Switch
Wires
(Brown/Brown)
Wires from
Water Temp Sensor
(Black/White)
Make connection
with connectors
provided
Fireman’s Switch
Wires from Heater
Cable to Bottom
PC Board
Cable to Top
PC Board
Figure 3-10
Figure 3-10
Factory
Installed
Wire Loop
Heater
Thermostat To
Max.
#14
Gauge Wire
Heater Toggle
Switch To On
Terminal 1
Terminal 2
Laars Heater Fireman’s
Switch Connection
Heater
Wiring
To
Mini-Wave
Control Center
Factory
Installed
Wire Loop
Heater
Thermostat To
Max.
#14
Gauge Wire
Heater Toggle
Switch To On
Terminal 1
Terminal 2
Laars Heater Fireman’s
Switch Connection
Heater
Wiring
To
Mini-Wave
Control Center
Figure 3-11
Figure 3-11
Figure 3-12
Figure 3-12
P7
Terminal
P7
Terminal