![Intermatic PE1501RC Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/intermatic/pe1501rc/pe1501rc_installation-and-user-manual_2077707041.webp)
Seven: Checking Out and Troubleshooting the System
41
Providing a brighter solution.™
Verify that the Hand-Held Remote is working properly
What to do
If it doesn’t work
Reference/Procedure
Wake up the Hand-Held
Remote by pressing any
button.
On the right hand side
of the display there
should be a “P” and “S”
indicating the pool and
spa set temperatures.
Use the arrow keys to
increase or decrease
these set points. The
display will change back
in five seconds.
Pushing the
<CHLR>
button should
change the display
to “CHLORINATOR
NOT AVAILABLE”. This
display will change back
in five seconds.
Holding down the
<P/S>
and
<CHLR>
buttons simultaneously
for five seconds should
enter you into the
programming screen.
Use the number keys to
navigate these menus.
Press the
<CHLR>
button to exit the
programming screen.
If you can’t complete
this procedure
successfully, follow the
steps in the next column
to troubleshoot.
1.
2.
3.
4.
Verify that batteries are
installed properly and fully
charged.
The Hand-Held Remote takes 3 AAA batteries. Make
sure the batteries are installed and are properly aligned
according to the polarity markings in the battery
compartment.
Do not mix fully charged batteries with partially
charged batteries in the Hand-Held Remote.
Do not use rechargeable batteries in the Hand-Held
Remote.
If the
Low Bat
indicator is visible in the display,
the Hand-Held Remote will function intermittently.
Replace batteries immediately.
1.
2.
3.
4.
Verify that the Hand-Held
Remote has successfully
awakened from its sleep
state.
Push any button on the Hand-Held Remote to wake it
from its sleep state. Failure to awaken means there will
be nothing visible on the display!
If the Hand-Held Remote is awake and none of its
buttons are pressed, it should go back into its sleep
state after one minute.
1.
2.
Verify that the Hand-Held
Remote is successfully
linked up to the Panel-
mounted Transceiver.
Check that the display panel on the Hand-Held Remote
says
STAT OK
, not just
STAT
.
If not, reprogram the Hand-Held Remote. See
pages
28-30
.
Replace the Hand-Held Remote if unable to
successfully program.
Replace the Panel-Mounted Transceiver if still not able
to establish communication with the replacement
Hand-Held Remote.