Chapter 4: Web configuration
216
NS3562-8P-2S User Manual
The page includes the following fields:
Object
Description
Mode
Enable or disable the per port PD Alive Check function.
By default, all ports are disabled.
Ping PD IP
Address
This column permits the user to set a PoE device IP address for pinging the
PoE device.
Note
: the PD’s IP address must be set to the same network segment as the
PoE switch.
Interval Time
(10~300s)
This column permits the user to set how long the system should issue a ping
request to a PD to detect if the PD is alive or dead.
Interval time range is from 10 to 300 seconds.
Retry Count (1~5)
This column permits the user to set the number of times the system retries
pinging the PD.
For example, if the count is set to 2, and the system retries pinging the PD and
the PD doesn’t respond continuously, the PoE port will be reset.
Action
Permits the user to set the action applied if the PD does not respond. The PoE
switch can perform the following three actions:
PD Reboot
: The system will reset the PoE port that is connected to the PD.
PD Reboot & Alarm
: The system will reset the PoE port and issue an alarm