Chapter 4: Web management
104
NS3550-8T-2S Industrial Managed Switch User Manual
5. Specify Port-8 to be the 802.1Q VLAN trunk port, and the trunking port must be a
tagged port during egress. The Port-7 configuration is shown below.
Both the VLAN 2 members of Port-1 to Port-3 and VLAN 3 members of Port-4 to
Port-6 belong to VLAN 1. But with different PVID settings, packets from VLAN 2 or
VLAN 3 are not able to access the other VLAN.
6. Repeat Steps 1 to 5 by setting up the VLAN trunk port at the partner switch and add
more VLANs to join the VLAN trunk. Repeat Steps 1 to 3 to assign the trunk port to
the VLANs.
Port isolate
The diagram below shows how the industrial managed switch handles isolated and
promiscuous ports, and how computers are not able to access the each other’s isolated
port. However, each computer requires access to the same server/AP/Printer. This
section explains how to configure the port for the server so that it can be accessed by
each isolated port.