Chapter 6: Command line mode
NS3550-8T-2S Industrial Managed Switch User Manual
443
VCL IP Subnet-based Vlan Add
Description:
Add or modify VCL IP Subnet-based VLAN entry. The maximum IPVlan entries are
limited to 128.
Syntax:
VCL IPVlan Add [<vce_id>] <ip_addr_mask> <vid> [<port_list>]
Parameters:
<vce_id>
: Unique VCE ID (1-128) for each VCL entry
<ip_addr_mask>
: Source IP address and mask (Format: a.b.c.d/n).
<vid>
: VLAN ID (1-4095)
<port_list>
: Port list or 'all', default: All ports
VCL IP Subnet-based Vlan Delete
Description:
Delete VCL IP Subnet-based VLAN entry.
Syntax:
VCL IPVlan Delete <vce_id>
Parameters:
<vce_id>
: Unique VCE ID (1-128) for each VCL entry
SMTP Command
SMTP Configuration
Description:
Show SMTP configure.
Syntax:
SMTP Configuration
Default Setting:
disable
SMTP Mode
Description:
Enable or disable SMTP configure.
Syntax:
SMTP Mode [enable|disable]
Parameters:
enable
: Enable SMTP mode
disable
: Disable SMTP mode
(default: Show SMTP mode)
Default Setting:
Disable
SMTP Server
Description: