Chapter 4: Web management
286
NS3550-8T-2S Industrial Managed Switch User Manual
2. Log in to switch 1 and select
Ring
>
Ring Wizard
.
3. Set “All Switch Number” = 3 and “Number ID” = 1. Click
Next
to set the ERPS
configuration for switch 1.
4. Set “MEP1” = Port 1, “MEP2” = Port 2, and VLAN ID = 3001. Click
Set
to save the
ERPS configuration for switch 1.
Set ERPS configuration on switch 2
1. Connect a PC directly to switch 2. Do not connect to port 1 or 2.
2. Log in to switch 2 and select
Ring
>
Ring Wizard
.
3. Set “All Switch Number” = 3 and “Number ID” = 2. Click
Next
to set the ERPS
configuration for switch 2.
4. Set “MEP3” = Port 2, “MEP4” = Port 1, and VLAN ID = 3001. Click
Set
to save the
ERPS configuration for switch 2.
Set ERPS configuration on switch 3
1. Connect a PC directly to switch 3. Do not connect to port 1 or 2.
2. Log in to switch 3 and select
Ring
>
Ring Wizard
.
3. Set “All Switch Number” = 3 and “Number ID” = 3. Click
Next
to set the ERPS
configuration for switch 3.