Chapter 6: Command line mode
NS3550-8T-2S Industrial Managed Switch User Manual
427
Syntax:
Erps vlan add <vid> <group-id>
Parameters:
<vid>
: VLAN ID (1-4095)
<group-id>
: protection group id 1 - 64
ERPS VLAN Delete
Description:
Disassociating a given vlan to a protection group
<vid> : protected vlan to be deleted
<group-id> : protection group-id for which vid belongs to.
Syntax:
Erps vlan delete <vid> <group-id>
Parameters:
<vid>
: VLAN ID (1-4095)
<group-id>
: protection group id 1 - 64
ERPS MEP
Description:
Associating Port 0/1 MEP to a protection group
<east_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 0
<west_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 1
<east_raps_mep> : Mep_ID for transmitting R-APS frames on Port 0
<west_raps_mep> : Mep_ID for transmitting R-APS frames on Port 1
<group_id> : protection group id for which mep is associating.
Syntax:
Erps mep <east_sf_mep> <west_sf_mep> <east_raps_mep> <west_raps_mep>
<group-id>
Parameters:
<east_sf_mep>
: SF mep id for Port 0
<west_sf_mep>
: SF mep id for Port 1
<east_raps_mep>
: CC/RAPS mep id for Port 0
<west_raps_mep>
: CC/RAPS mep id for Port 1
<group-id>
: protection group id 1 - 64
ERPS RPL Neighbour
Description:
Selection of RPL neighbour for a protection group
(east|west) : selected east(Port 0) or west(Port 1) as RPL neighbour
<group-id> : protection group id for selecting RPL Block.
Syntax:
Erps rpl neighbour <rpl_port> <group-id>
Parameters:
<rpl_port>
: RPL Block
<group-id>
: protection group id 1 - 64