Chapter 4: Web management
NS3550-8T-2S Industrial Managed Switch User Manual
153
3. Create a QoS profile that associates a service level and a classifier.
4. Apply a QoS profile to a port(s).
Port policing
The QoS Ingress Port Policers page permits configuration of the policer settings for all
switch ports.
The page includes the following fields:
Object
Description
Port
The port number for which the configuration below applies.
Enable
Controls whether the policer is enabled on this switch port.
Rate
Controls the rate for the policer. The default value is 500. This value is
restricted to
100
-
1000000
when the Unit is
kbps
or
fps
, and it is restricted to
1
-
3300
when the Unit is
Mbps
or
kfps
.
Unit
Controls the unit of measure for the policer rate as
kbps
,
Mbps
,
fps
, or
kfps
. The default value is
kbps
.
Flow Control
If flow control is enabled and the port is in flow control mode, then pause
frames are sent instead of discarding frames.
Buttons
• Click
Save
to save changes.
• Click
Reset
to undo any changes made locally and revert to previously saved
values.