P. 49
4-8 Hold Input
Movement Example: Temporary stops the movement of the actuator.
Method:
Uses the Hold Input.
P L C
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Section
P24
N
Signal Name
+24V
0V
Start
Command Position 1
Command Position 2
Command Position 4
Command Position 8
Connection Forbid
Hold
Connection Forbid
Compelete Position 1
Comeplete Position 2
Complete Position 4
CompletePosition 8
Positioning Complete
Homing Complete
Zone
Alarm
Emeregency Stop
Connection Forbid
Output
Input
Input
1
7
3
1
Select Input Assigned Command Position
2
Start Input ON
Start Transfer to Assign Position
3
4
Start Input OFF
5
HOLD Input OFF
(At that spot, temporary stops)
RCP Controller
8
6
Hold Input ON
(At that spot, transfer start )
7
Positioning Complete Output ON
8
Output Complete Position
Transfer Complete to Assigned Position
6 5
PIO
4. Application (Practice)
Flow
Positioning Complete Output OFF
Complete Position OFF
*
* Positioning Complete ON and Complete Position
Output both have the same timing.
2
4