P. 14
Dip Switch Number 1~4
• • •
Axis Number Setting Switch:
When connecting more than 2 axes onto the SIO connector, serial reorganization occurs when setting the actuator axis number. You
may set up to 0~15 axes (at the time of shipment, numbers 1~4 are all set as OFF. This application is for 1 axis, single unit).
Dip Switch Number
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
OFF
ON
OFF
0N
OFF
ON
OFF
ON
0FF
ON
OFF
ON
OFF
ON
OFF
ON
Axis Number
2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Caution:
Please do not adjust dip switch numbers 5 &6. Please do not adjust the setting that was done at the time of
shipping. Any missetting will not only limit basic functions, but will also, lead to a breakdown.
In case of number of axes greater than 1, the emergency stop of the teaching pendant will only effect the controller
axis connected to the teaching pendant.
2. Specifications
Please note:
The controller link cable length is 200mm.
The controller can connect up to a maximum of 16 units.