Intel
®
Server System SR1600UR Service Guide
47
Figure 32. Removing the Processor Air Duct
Installing the Processor Air Duct
Place the processor air duct over the processor socket(s) (see
Figure 33
). The front edge of
the air duct should align correctly with the notches on the fan module. Use caution not to
pinch or disengage cables that may be near or under the air duct.
Figure 33. Installing the Processor Air Duct
Installing and Removing Memory
The silkscreen on the board displays DIMM A1, DIMM A2, DIMM B1, DIMM B2,
DIMM C1, DIMM C2 for DIMMs on CPU socket 1 and DIMM D1, DIMM D2, DIMM
E1, DIMM E2, DIMM F1, DIMM F2 for DIMMs on CPU socket 2.
AF002
88
2
Processor
Air
Duct
AF002
88
3