Server System SR1600UR Service Guide
89
Figure 77. Removing Power Supply Module from the Server System
3. Insert the replacement power supply module into the power supply cage until it
clicks into place.
Figure 78. Installing Power Supply Module into the Server System
4. Reconnect all power cables.
Replacing the Control Panel Module (Hot-swap Hard
Drive System only)
Your server system must be operated with a control panel installed.
Note:
The Intel
®
Local Control Panel is only supported in hot-swap hard drive systems.
Caution:
The control panel is NOT hot-swappable. Before removing or replacing the control panel,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
1. Unplug the front panel and USB cables from the backplane (see letters “A” and “B”
in
Figure 79
).
2. Press the latch at the back of the control panel and push it forward (see letter “C” in
Figure 79
).
AF000
3
66
A
B
A
AF000
3
67
A
B
B
Содержание SR1600UR - Server System - 0 MB RAM
Страница 4: ...iv Intel Server System SR1600UR Service Guide...
Страница 6: ...vi Intel Server System SR1600UR Service Guide...
Страница 8: ...viii Intel Server System SR1600UR Service Guide...
Страница 14: ...xiv Intel Server System SR1600UR Service Guide...
Страница 18: ...xviii Intel Server System SR1600UR Service Guide...
Страница 58: ...40 Intel Server System SR1600UR Service Guide Figure 25 Installing the Server System Cover TP02196 A B...
Страница 122: ...104 Intel Server System SR1600UR Service Guide...
Страница 126: ...108 Intel Server System SR1600UR Service Guide...
Страница 132: ...114 Intel Server System SR1600UR Service Guide...
Страница 142: ...124 Intel Server System SR1600UR Service Guide...
Страница 166: ...148 Intel Server System SR1600UR Service Guide...
Страница 190: ...172 Intel Server System SR1600UR Service Guide...