Intel
®
Server System SR1600UR Service Guide
87
12. If necessary, install the Intel
®
RMM3. For instructions, see
“Installing the Intel
®
RMM3” on page 71
.
13. Install the processor air duct. For instructions, see
“Installing the Processor Air
Duct” on page 47
.
14. Install the PCI riser assembly. For instructions, see
“Installing the PCI Riser
Assembly” on page 42
.
Replacing the Backup Battery
The lithium battery on the server board powers the RTC for up to 10 years in the absence
of power. When the battery starts to weaken, it loses voltage, and the server settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your
customer service representative or dealer for a list of approved devices.
Warning:
Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries
according to manufacturer's instructions.
Advarsel:
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
Advarsel:
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning:
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
instruktion.
Varoitus:
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
1. If installed, remove the PCI riser assembly. For instructions, see
“Removing the
PCI Riser Assembly” on page 41
.
2. If installed, remove the processor air duct. For instructions, see
“Removing the
Processor Air Duct” on page 46
.
3. Locate the battery.
4. Insert the tip of a small flat bladed screwdriver, or an equivalent, under the tab in
the plastic retainer. Gently push down on the screwdriver to lift the battery.
5. Remove the battery from its socket.
Содержание SR1600UR - Server System - 0 MB RAM
Страница 4: ...iv Intel Server System SR1600UR Service Guide...
Страница 6: ...vi Intel Server System SR1600UR Service Guide...
Страница 8: ...viii Intel Server System SR1600UR Service Guide...
Страница 14: ...xiv Intel Server System SR1600UR Service Guide...
Страница 18: ...xviii Intel Server System SR1600UR Service Guide...
Страница 58: ...40 Intel Server System SR1600UR Service Guide Figure 25 Installing the Server System Cover TP02196 A B...
Страница 122: ...104 Intel Server System SR1600UR Service Guide...
Страница 126: ...108 Intel Server System SR1600UR Service Guide...
Страница 132: ...114 Intel Server System SR1600UR Service Guide...
Страница 142: ...124 Intel Server System SR1600UR Service Guide...
Страница 166: ...148 Intel Server System SR1600UR Service Guide...
Страница 190: ...172 Intel Server System SR1600UR Service Guide...