116
Intel
®
Server System SR1600UR Service Guide
Figure 89. Diagnostic LED Placement Diagram
AF003045
C
B
A
A.
System Status LED
B.
System Identification LED
C.
POST Code Diagnostic LEDs
Table 8. Diagnostic LED POST Code Decoder
Checkpoint
Diagnostic LED Decoder
Description
O=On; X=Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
Multi-Use Code (This beep code is used in different contexts)
0xF2h
O
O
O
O
X
X
O
X
Seen at the start of Memory Reference
Code (MRC)
Start of the very early platform
initialization code
Very late in POST, it is the signal that the
OS has switched to virtual memory
mode
Memory Error Codes (Accompanied by a beep code)
0xE8h
O
O
O
X
O
X
X
X
No Usable Memory Error: No memory in
the system, or SPD bad so no memory
could be detected
OxEAh
O
O
O
X
O
X
O
X
Channel Training Error: DQ/DQS
training failed on a channel during
memory channel initialization.
0xEBh
O
O
O
X
O
X
O
O
Memory Test Error: memory failed
Hardware BIST.
Содержание SR1600UR - Server System - 0 MB RAM
Страница 4: ...iv Intel Server System SR1600UR Service Guide...
Страница 6: ...vi Intel Server System SR1600UR Service Guide...
Страница 8: ...viii Intel Server System SR1600UR Service Guide...
Страница 14: ...xiv Intel Server System SR1600UR Service Guide...
Страница 18: ...xviii Intel Server System SR1600UR Service Guide...
Страница 58: ...40 Intel Server System SR1600UR Service Guide Figure 25 Installing the Server System Cover TP02196 A B...
Страница 122: ...104 Intel Server System SR1600UR Service Guide...
Страница 126: ...108 Intel Server System SR1600UR Service Guide...
Страница 132: ...114 Intel Server System SR1600UR Service Guide...
Страница 142: ...124 Intel Server System SR1600UR Service Guide...
Страница 166: ...148 Intel Server System SR1600UR Service Guide...
Страница 190: ...172 Intel Server System SR1600UR Service Guide...