Intel® Quiet System Technology (Intel® QST)
68
Thermal and Mechanical Design Guidelines
7.2
Board and System Implementation of Intel
®
QST
To implement the board must be configured as shown in Figure
7-3 and listed below:
ME system (S0–S1) with Controller Link connected and powered
DRAM with Channel A DIMM 0 installed and 2 MB reserved for Intel QST FW
execution
SPI Flash with sufficient space for the Intel QST Firmware
SST-based thermal sensors to provide board thermal data for Intel QST algorithms
Intel QST firmware
Figure
7-3. Intel
®
QST Platform Requirements
Processor
ME
SPI
Flash
Intel®
ICH8
DRAM
Controller Link
DRAM
FSC
Control
SPI
SST
Sensor
Intel® (G)MCH
ME
Note:
Simple Serial Transport (SST) is a single wire bus that is included in the ICH8 to
provide additional thermal and voltage sensing capability to the Intel Management
Engine (ME).
Содержание BX80570E8200 - Core 2 Duo 2.66 GHz Processor
Страница 10: ...10 Thermal and Mechanical Design Guidelines...
Страница 26: ...Processor Thermal Mechanical Information 26 Thermal and Mechanical Design Guidelines...
Страница 82: ...Heatsink Clip Load Metrology 82 Thermal and Mechanical Design Guidelines...
Страница 84: ...Thermal Interface Management 84 Thermal and Mechanical Design Guidelines...
Страница 108: ...Balanced Technology Extended BTX System Thermal Considerations 108 Thermal and Mechanical Design Guidelines...
Страница 110: ...Fan Performance for Reference Design 110 Thermal and Mechanical Design Guidelines...
Страница 122: ...Mechanical Drawings 122 Thermal and Mechanical Design Guidelines Figure 7 50 Reference Fastener Sheet 1...
Страница 123: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 123 Figure 7 51 Reference Fastener Sheet 2...
Страница 124: ...Mechanical Drawings 124 Thermal and Mechanical Design Guidelines Figure 7 52 Reference Fastener Sheet 3...
Страница 125: ...Mechanical Drawings Thermal and Mechanical Design Guidelines 125 Figure 7 53 Reference Fastener Sheet 4...