Command Overview INSYS WLAN serial
39
Command Description
AT#RAT
=
Set data rate (in Mbps)
AT#RAT
=1
"Fixed 1 Mbps"
AT#RAT
=2
"Fixed 2 Mbps"
AT#RAT
=3 "Auto
Fallback"
(default)
AT#RAT
=4
"Fixed medium rate"
AT#RAT
=5
"Fixed high rate"
AT#RAT
=6
"Auto fallback standard"
AT#RAT
=7
"Auto fallback medium"
The setting
AT#RAT
is immediately stored in the permanent memory (independent from
the command
AT&W
). The setting will only take effect with Reboot (
AT#RBT
).
AT#RBT
AT#RESET
Reboot
The device is rebooted. All network parameters are reloaded from the permanent
memory.
ATS0
=
Number of ringing tones until automatically going off-hook.
ATS0
=n
determines the number of ringing tones (received packets), after which it
automatically goes off-hook.
ATS0
=1
goes off-hook when the local port is first accessed (default)
ATS0
=0
deactivates automatically going off-hook when the local port is accessed.
For UDP/IP connections, ringing tones represent single (also empty) UDP/IP network
packets. For TCP/IP connections, connection requests of a remote terminal („
SYN
“) are
recognized as ringing tones.
While the UDP connection is established, the modules send an empty UDP data packet in
the beginning, so the remote terminal device accepts the connection if it is configured
with
ATS0
=1
.
Important difference to modems: In TCP/IP mode, for S0=0 the connection acceptance is
completely blocked, i.e. „
RING
“ is not displayed for a connection request.
For manual connection acceptance, So=200 should be set.
ATS1?
Number of received packets for connection request
Query of the number of TCP-SYN packets. This registry is used to achieve a behavior such
as, for example, S0=2.
ATS2=
Character for escape sequence
The escape sequence consist of a series of a 1 second pause, 3 times the escape character
and 1 second pause again. (The pre and post run time of 1 second can be changed using
ATS12)
ATS2=n
n=0...127
Determination of the escape character as ASCII code
n=43
Default setting „+“
n>127 Functionality
deactivated
The setting is stored in the permanent memory with AT&W.
ATS3=
Carriage Return – CR
ATS3=n
n=0...127
Determination of the character as ASCII code
n=13 Default
setting
The setting is
not
stored with AT&W in the permanent memory.
version 1.01 / 10.04
Содержание WLAN bridge
Страница 1: ...Operating Manual INSYS WLAN bridge WLAN serial Version 1 01 10 04 ...
Страница 6: ......