Chapter 4 Parameter Description
31
FH-28
maximum
line speed
0.1
m/Min~6500.0m
/Min
0.1m/Min
1000.0m/Min
When obtaining line speed through analog input, the maximum line
speed must be correctly set. The maximum value of analog input
corresponds with the value.
FH-29
minimum line
speed for curling
radius calculation
0.1
m/Min~6500
m/Min
0.1m/Min
200.0m/Min
Set the minimum speed for starting calculation of curling radius. When
the inverter detects that the line speed is lower than the value, inverter
will stop curling radius calculation. Correct setting of the value will
effectively avoid great deviation of curling radius calculation when the
speed is reduced. In general, the value shall be set to over 20% of
maximum line speed.
FH-30
Actual line
speed
0.1 m/Min~6500.0m/Min
―――
―――
The parameter will display actual line speed on line.