32, 33: Initial curling radius selection terminal, used to select the initial
curling radius value.
34: Pre-drive command terminal. When the terminal is active, the
inverter operates in pre-drive mode. When the terminal is inactive, the
inverter operates in tension control mode.
35: Turn calculation signal. When calculating the curling radius with the
thickness accumulation method, this signal is used to calculate the
turns of the shaft rotation.
36, 37: reserved.
38: wind-up/roll-down switching. When the terminal is active, the actual
curling mode is the inverted setting of FH-01.
39: Curling radius calculation stop terminal. It is used when it is
necessary to pause the calculation of the curling radius.
40, 41: thickness selection terminal, used to select the setting source
for digital setting thickness.
42: Tension control disable terminal. When this terminal is active, it is
equivalent to the situation that FH-00 is set as 0.
43: Tension increase terminal. When this terminal is active, the control
tension will be increased according to the proportion set in FH-57.
F5-07~F
5-09
analog
output
selectio
n
12: external taper control
output
13: curling radius output:
0%~100% corresponds to
0~maximum curling radius
14: actual tension (after taper
calculation)