Chapter 4 Parameter Description
27
When curling radius source FH-10 selects 2, 3, 4, 5, the parameter
must be set. The maximum input corresponds to the maximum curling
radius. When the inverter calculates its curling radius, the calculation
will be limited by the parameter.
FH-12
winding shaft
diameter
1mm~10000mm
1
100
Set the diameter of the winding shaft. If the parameter is not properly
set and the curling radius of the inverter is lower than the set value, the
diameter will be limited by the parameter.
FH-13
initial curling
radius source
0: FH-14~FH-16
setting
1: AI1 setting
2: AI2 setting
3: AI3 setting
1
0
Select the input channel of initial curling radius.
0: It is allowed to set three initial curling radii with number for
FH-14~FH-16.
1:AI1 2:AI2 3:AI3 the initial curling radius is determined by analog value.
Select different ports for analog input.
When roll-down, select one terminal as initial curling radius. Select
terminal 1, connect to COM, and set initial curling radius in FH-14. Then,
when resetting the curling radius, it can be reset to the initial curling
radius of roll-down.
Note: The initial value of curling radius can be determined through two
multi-function terminals. For example, select DI3,DI4 ports to determine
the value of initial curling radius. Set DI3 port parameter F4-02 to