Chapter 4 Parameter Description
41
taper. When the roll is used as tension feedback, what the inverter
controls is the position of the roll rather than the tension of the material.
The tension control is decided by the force of the roll.
This function code is used to select the maximum output setting mode.
0: set by FH-54
1, 2, 3: select to be controlled by analog input
FH-54
external taper
control maximum
output digital
setting
0.0%~100.0%
0.1%
100.0%
When FH-54 is set as 0, the initial output is set by the function code.
FH-55
pre-drive curling
radius calculation
selection
0: calculate
1: stop
calculation
1
0
Select whether the curling radius calculation is stopped upon pre-drive.
In general, the curling radius calculation shall be stopped.
FH-56
curling radius
calculation stop
delay after ending
of pre-drive
0.0s~10.0s
0.1s
5.0s
If curling radius calculation is stopped upon pre-drive, this function code
will decide when the curling radius calculation starts after the pre-drive
is ended, so as to prevent the curling radius causing too large
fluctuation at the instant of the pre-drive ending.
FH-57
tension
increase ratio
0.0%~200.0%
0.1%
50.0%