4.1 Selection of Control Mode
FH-00
Tension
control mod
e
0: inactive
1: Open-loop torque control
mode
2: Close-loop speed control
mode
3: Close-loop torque control
mode
4: Constant line speed
control mode
0
1. Select the tension control mode with the parameter
1) Don’t choose tension control mode. The tension control is inactive,
and the inverter is used as general inverter.
2) Open-loop torque control mode: No tension test and feedback is
required. The inverter controls the tension of the material through
controlling output torque. The output torque controlled by inverter can
realize better control under the speed sensor vector control.
3) Close-loop speed mode: Tension test and feedback are required.
The inverter controls output frequency through PID close-loop to enable
the set tension is met. The inverter controls output frequency through
speed sensorless vector control, V/F control or close-loop vector
control.
4) Close-loop speed mode: Tension test and feedback are required.