Chapter 3 Function Parameter Table
14
Function
code
Name
Set range
Mini
mum
unit
Leave-fa
ctory set
value
Chan
ge
FH-43
differential time
D2
0.000s~1.000s
0.001
s
0.000s
○
FH-44
auto
adjustment
basis for PID
parameters
0: Only the first
group of PID
parameters are
used
1: Adjust
according to the
curling radius
2: Adjust
according to the
operating
frequency
3: Adjust
according to the
line speed
1
0
○
Auto roll alternation parameter
FH-45FH
-45
pre-drive
speed gain
-50.0%~+50.0%
0.1%
0.0%
○
FH-46
pre-drive
torque limit
selection
0: F2-09 setting
1: Set the limit
according to
tension setting
1
0
○
FH-47FH
-47
pre-drive
torque gain
-50.0%~+50.0%
0.1%
0.0%
○