OPERATOR SETTINGS FOLDER
•
PAGES 1: OPERATOR SETTINGS
Figure 41 : Operator Settings
The parameters below are adjustable at any time:
Table 16 : Operator Settings
Operator
Settings
Default
Min.
Max.
Step
Unit
Target Pressure
100
65
145
1
psi
Automatic Stop
Pressure
110
1
10
1
psi
Immediate Stop
Pressure
120
Auto
Auto+10
1
psi
% Savings
Compared To
Modulation
---
---
---
---
Energy Rate
0.000
0.000
9999.999
---
---
Reset Averaging
--/--/--
-
-
-
Date
Condensate
Release
5
2
20
1
Sec
Condensate
Interval
180
90
270
1
Sec
•
PAGES 2-3: OPERATOR OPTIONS
Figure 42 : Operator Options
The parameters immediately below are only adjustable when the compressor
is stopped.
The options set points are similar to the operator set points except these set
points cannot be changed while the compressor is running.
Table 17 : Operator Options
Option
Items
Selection
Min.
Max.
Step
Unit
Installed
option
required?
Remote
Sensor
ON/OFF
---
---
---
---
No
Comm
Control
ON/OFF
---
---
---
---
No
Remote
Start-Stop
ON/OFF
---
---
---
---
No
Enable
PORO
ON/OFF
---
---
---
---
Yes
PORO Time
---
10
600
1
Sec
Yes
Scheduled
Start Day
---
Day
Day
1
Day
Yes
Scheduled
Start Hour
---
00:00
23:59
1
Time
Yes
Scheduled
Stop Day
---
Day
Day
1
Day
Yes
Scheduled
Stop Hour
---
00:00
23:59
1
Time
Yes
If an option has not been purchased and installed in the compressor, the
message “Not Installed” will be shown on the selection display screen.
Installation of options will be done using the
Ingersoll Rand
service tool.
* The low ambient temperature is only adjustable if the low ambient factory
set point is ON.
** A value of 0 will disable the lead/lag cycle time feature.
RELEASED 01/Nov/2018 12:06:37 GMT