80446339 Rev E
EN-13
EN
DASHBOARD STATUS MESSAGES
The dashboard also displays the current operating state of the compressor.
The following states can be encountered during machine operation:
•
Ready to Start
– The compressor currently has no trip or start inhibit
conditions present. The machine can be started by pressing the start
button at any time.
•
Starting
– A start command has been given to the compressor and the
start sequence is being performed. The time period for this state can vary
depending on the starter type of the machine.
•
Load Delay
– The compressor is waiting for a small period of time after
starting before allowing the machine to load. This ensures the machine is
at operating conditions before loading
•
Running Loaded
– The compressor is operating and producing air. The
inlet valve is open and the blowoff valve is closed.
•
Running Unloaded
– The compressor is operating, but not producing air.
The inlet valve is closed and the blowoff valve is open.
•
Auto-Restart
– The compressor has stopped due to pressure rising above
the offline or auto-stop setpoints and auto-restart being enabled. The
compressor will automatically restart when pressure falls to the online or
target pressure setpoint.
•
Stopping
– The compressor has received a stop command and the stop
sequence is being performed.
•
Blowdown
– The compressor must wait for a brief period of time after
stopping its motor before it is allowed to start again.
•
Not Ready
– The compressor has detected a condition that will not allow
the compressor to start. The condition must be cleared before a start is
allowed, but does not need to be acknowledged.
•
Tripped
– The compressor has detected an abnormal operational
condition that has stopped the machine. A trip must be acknowledged by
hitting the reset button before the compressor can start.
•
Processor Init
– The controller is being initialized.
FOLDER OPTIONS FIXED SPEED
HOME FOLDER
•
PAGE 1 – SYSTEM OVERVIEW
Figure 7 : Home Folder
This is the factory default display after powering up the system.
•
Load Pressure
is indicated in the white box and by the white arrow,
which is always left of center on the gauge. The compressor will load
when package discharge pressure falls below this value.
•
Unload Pressure
is indicated in the white box and by the white arrow,
which is always right of center on the gauge. The compressor will unload
when package discharge pressure rises above this value.
•
Package Discharge Pressure
is indicated by the large numbers centered
below the gauge and by the red arrow.
•
Pressure Unit of Measure
is indicated below the Package Discharge
Pressure. This is selectable from the General Settings folder.
•
Airend Discharge Temperature
is indicated by the numbers in the lower
left of the display.
•
Temperature Unit of Measure
is indicated to the right of the Airend
Discharge Temperature. This is selectable from the General Settings folder.
•
Run Hours
indicate the number of hours the compressor has been
running.
•
PAGE 2 : COUNTERS
Figure 8 : Counters
•
Hour Meters
indicate the hours that: the controller has been powered
up, the compressor has been running, and the compressor has running
loaded.
•
Starts
indicate the number of times a start is attempted on the
compressor.
•
Date & Time
is adjustable and configurable in the General Settings folder.
•
PAGES 3-4: ANALOG INPUTS
Figure 9 : Analog Inputs
Icon
Meaning
Pressure
Temperature
NOTICE
All information on these pages is read only.
RELEASED 01/Nov/2018 12:06:37 GMT