80446339 Rev E
EN-15
EN
•
PAGES 6-7: SENSOR CALIBRATION
Figure 12 : Sensor Calibration
Sensor calibration can only take place when the compressor is stopped.
There should be no pressure on a sensor when it is calibrated. Calibration
only needs to take place after a sensor is replaced, the controller is replaced,
or the operator suspects the sensor reading is in error. Calibrate a sensor by
selecting the checkbox beside the sensor name.
Each of the sensors listed below can be calibrated:
• Inlet Vacuum (1AVPT)
• Sump Pressure (3APT)
• Package Discharge Pressure (4APT)
• Coolant Filter Inlet Pressure (5CPT)
• Coolant Filter Outlet Pressure (6CPT)
• Remote Pressure (10APT) – Only on compressors with the remote sensor
option
• Interstage Pressure (2APT) – Only on 2-stage compressors
• After-cooler Discharge Pressure (7APT) – Only on compressors with
integrated dryer
Please note that if a sensor is currently reading a value that is +/- 10% of
its range from zero, the sensor will not be able to be calibrated. Please
make sure the sensor is being exposed to atmosphere before attempting
calibration.
Table 10 : Operator Options
Operator Options
Selection
Min.
Max.
Def.
Step
Unit
Installed option
required?
Enable Auto Restart
ON/OFF
---
---
OFF
---
---
No
Auto-Restart Time
---
2
60
10
1
Min
No
Auto-Restart Delay Time
---
0
60
0
1
Sec
No
Communications Control
ON/OFF
---
---
OFF
---
---
No
Remote Start/Stop
ON/OFF
---
---
OFF
---
---
No
Power Out Restart
ON/OFF
---
---
OFF
---
---
Yes
Power Out Restart Time
---
10
600
10
1
Sec
Yes
Low Ambient Temp*
---
30
60
35
1
Deg F
No
Lead/Lag Cycle Time**
---
0
750
0
1
Hours
No
Scheduled Start - Day
---
Day
Day
Sun
1
Day
Yes
Scheduled Start
---
00:00
23:59
00:00
1
Time
Yes
Scheduled Stop - Day
---
Day
Day
Sun
1
Day
Yes
Scheduled Stop
---
00:00
23:59
00:00
1
Time
Yes
Enable High Dust Filter
ON/OFF
---
---
OFF
---
---
Yes
Enable VSD
ON/OFF
---
---
OFF
---
---
Yes
Remote Sensor
ON/OFF
---
---
OFF
---
---
Yes
* The low ambient temperature is only adjustable if the low ambient factory set point is on.
** A value of 0 will disable the lead/lag cycle time feature.