21
INS
TALL
AT
O
RE
U
TENTE
MANU
TENT
O
RE
14
1.15 ROOM CHRONO-THERMOSTATS (OPTIONAL).
The indoor unit is prepared for the application of room chrono-
thermostats, which are available as optional kits (Fig. 14).
ATTENTION:
the control panel must be installed even
when using a room chrono-thermostat
The room chrono-thermostat is used when the room
probe of the control panel is deactivated.
It must be connected to terminals 1 and 2 as shown on the wiring
diagram. Make sure that the On/Off contact of the thermostat is
of the “clean” type.
The connections must be made on the terminal board inside the
indoor unit control panel. To disassemble the cover to access the
control panel, refer to Par. 1.11.
ATTENTION:
the outlet of terminals 1 and 2 of the
remote panel is at 230V / 50Hz
All Immergas chrono-thermostats are connected with 2 wires
only. Carefully read the user and assembly instructions contai-
ned in the accessory kit.
ATTENTION:
Disconnect power to the Victrix Hybrid
appliances before any electrical connec-
tion.
The Immergas chrono-thermostat allows:
- set two room temperature values: one for day (comfort tempe-
rature) and one for night (reduced temperature);
- set a weekly programme with four daily switch on and switch
off times;
- select the required operating mode from the various possible
alternatives:
• manual mode (with adjustable temperature).
• automatic mode (with set programme).
• forced automatic mode (momentarily changing the temperature
of the automatic programme).
The Immergas chrono-thermostat is powered by two 1.5V LR 6
type alkaline batteries;
1.16 230 VAC CONFIGURABLE OUTLET.
A configurable relay is available on the P.C.B. of the indoor unit, its
outlet is available on terminals 5 and 6 (to disassemble the cover
to access the connections compartment of the control panel refer
to Par. 1.11.) The configurations that can be set for parameter “P3”
are listed in the P.C.B. programming paragraph.