1.33 COMMISSIONING OF THE COMBUSTION UNIT
(IGNITION).
For Victrix Hybrid heat pump commissioning (the operations
listed below must only be performed by qualified personnel and
in the presence of staff only):
- check that the internal system is properly sealed according to
the regulations in force;
- ensure that the type of gas used corresponds to the boiler settings;
- check connection to a 230V-50Hz power mains, correct L-N polarity
and earthing connection;
- Check that there are external factors that may cause the formation
of fuel pockets;
- switch the boiler on and ensure correct ignition;
- make sure that the gas flow rate and relevant pressure values
comply with those given in the manual (Par. 4.2);
- ensure that the safety device is engaged in the event of gas supply
failure and check activation time;
- Check the intervention of the main switch located upstream from
the indoor unit and in the unit;
- check the intervention of the main switch located upstream from
the boiler and in the boiler;
- check that the intake and/or exhaust terminals (if fitted) are not
blocked.
- Carry out the flue test.
The system must not be started up even if only one of the checks
should be negative.
1.34 KITS AVAILABLE ON REQUEST.
• System shut-off valves kit. The indoor unit is designed for in-
stallation of system interception cocks to be placed on flow and
return pipes of the connection assembly. This kit is particularly
useful for maintenance as it allows the indoor unit to be drained
separately without having to empty the entire system.
• Polyphosphate dispenser kit (only for indoor installation). The
polyphosphate dispenser reduces the formation of lime-scale
and preserves the original heat exchange and domestic hot water
production conditions. The indoor unit is prepared for applica-
tion of the polyphosphate dispenser kit.
• Cover Kit. If installed outdoors in a partially protected place with
direct air intake, it is compulsory to mount the appropriate top
protective cover for the correct functioning of the indoor unit
and to protect it from adverse weather conditions.
• Cycloidal filter kit (on request). The magnetic cycloidal filter is
able to detect the ferrous residues present in the system's water.
Thanks to the two cocks in the kit, it facilitates maintenance by
cleaning the filter without having to empty the circuit.
The above-mentioned kits are supplied complete with instructions
for assembly and use.