-43-
7.5.6 Ground Continuity Test
Conditions:
Perform a measurement after the AC power cord is disconnected.
Measuring instrument: Earth Resistance Tester
Requirements:
•
Measured with Earth Resistance Tester:
Resistance is 0.1
Ω
or less
Measurement:
Between the earth terminal of the three-core power inlet and ground terminal of the
unit.
7.5.7 Foreign Material Verification
Conditions:
Shake the whole unit.
Requirements:
•
No unusual sound is heard.
7.5.8 Test Equipment Connection
Requirements:
•
Equipments are connected to the LPX100 projector following the chart in “7.2 Test
Equipment Connection”. (Except for S-VIDEO equipment).
7.5.9 FAN Alarm Function
Conditions:
Remove the Air Filter and plug the AC power cord, then press the <ON/STANDBY>
key in the Standby mode.
Requirements:
•
Sponge is attached to the Air Filter.
•
The Fan does not rotate.
•
The Lamp is not turned on.
•
The POWER LED blinks red.
Measurement:
Air Filter
Fan
Lamp
Key Panel