7.5.3 Insulation Resistance Test
Conditions:
Measuring instrument: Insulation Resistance Tester (500V Megger)
Applied voltage:
500 DAC
Applied terminals:
Between FG and AC
Requirements:
•
10M
Ω
or greater
Measurement:
Between FG and AC
7.5.4 Leak Current Test
Conditions:
Measuring instrument: Leakage Current Tester
Operating voltage:
240VAC 50Hz
Measure at the maximum current load mode when the lamp is on.
Requirements:
•
1mA or less
Measurement:
Between FG and ground
7.5.5 Power Consumption Test
Conditions:
Lamp:
ON
Input:
PC
Operating voltage:
100VAC 50Hz
Measuring instrument: AC Wattmeter
Requirements:
•
230W or less
Measurement: