![Iiyama LPX100 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/iiyama/lpx100/lpx100_maintenance-manual_624400036.webp)
-29-
6.4.5 ASO Adjustment Value Input
Conditions
None.
Requirements:
•
Input the adjustment value of the ASO-02PKG unit test in the test result form
according to the Adjustment Value Form.
Items to be input are:
Eight items in
Adjust PC Image PC VIDEOAMP
adjustment and eight items in
Adjust VIDEO Image PC VIDEOAMP
adjustment.
Measurement:
None.
Adjustment Procedures:
AMP_BIAS, AMP_R_BIAS, AMP_G_BIAS, AMP_B_BIAS,
AMP_GAIN, AMP_R_GAIN, AMP_G_GAIN, AMP_B_GAIN
6.4.6 COM Adjustment
Conditions
Input:
PC
PC input signal: VG-Prog. No. 856
XGA 60Hz
Test pattern:
CROSS
(Pattern with alternating black and white stripes aligned one by one)
Lower the output level of the Signal Generator to 50% white.
Requirements:
•
Adjust the flicker patterns of R/G/B with
LCD1(CXA/6050) COM
operation to
minimize flicker.
Measurement:
Projected image
Adjustment Procedures:
LCD1 COM R_LCCOM,
LCD1 COM G_LCCOM,
LCD1 COM B_LCCOM