-iii-
How to perform insulation check
Unplug the equipment from the outlet and disconnect all the wires and cables connected to
the equipment. Then, check that the insulation resistance between each plug and the
externally exposed metallic sections
(Note)
of respective terminals is 10 M
Ω
or larger, using
a 500V insulation resistance meter.
Note) Externally exposed metallic sections: VIDEO input terminal, S-VIDEO input
terminal, PC input terminal, test terminal