-41-
7.5 Inspection / Verification Procedures
*Note
•
Carry out these tests after the Economy mode is turned off.
7.5.1 Temperature Alarm Test
Conditions:
•
Operate the LPX100 projector continuously for 30 minutes at room temperature.
•
Operate the LPX100 projector continuously raising an ambient temperature.
Requirements:
•
The lamp does not go out and the TEMP LED is not lit (Temperature Alarm
function is not performed).
•
The lamp goes out and the TEMP LED is lit (Temperature Alarm function is
performed).
Measurement:
Key Panel
Lamp
7.5.2 Safety Test, Dielectric Strength Test
Conditions:
Perform a measurement after the AC power cord is plugged.
Measuring instrument: Dielectric Strength Tester
Applied voltage:
1600VAC 50Hz
Applying time:
3 seconds
Leak current setting:
20mA
Applied terminals:
Between FG and AC
Requirements:
•
“NG” is not indicated on the tester.
•
There is no electrical breakdown.
Measurement:
Between FG and AC
Dielectric Strength Tester display