21
INSTALING THE UNIT
•
Decide the installation location regarding the following conditions
and obtain the user’s approval.
•
The outdoor unit must not be placed on its side or upside down, as the compressor lubrication oil will run into the
cooling circuit and seriously damage the unit.
•
Choose a location that is dry and sunny, but not exposed to direct sunlight or high winds. Do not
block any passageways or thoroughfares.
•
Choose a location where the noise of the Air to Water Heat Pump when running and the discharged air does not
disturb any neighbors.
•
Choose a position that enables the pipes and cables to be easily connected to the other hydraulic system.
•
Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
noise and vibration.
•
Position the outdoor unit so that the air flows directly toward the open area. Place the outdoor unit where there
are no plants and animals because they may cause malfunction of the outdoor unit. Maintain sufficient
clearance around the outdoor unit, especially from a radio, computer, stereo system, etc.
Installation Guide
at the Seashore
Make sure to follow the guides below when installing at the seashore.
1.
Do not install the product in a place where it is directly exposed to seawater and sea breeze.
-
Make sure to install the product behind a structure (such as a building) that can block the sea breeze.
-
Even when it is inevitable to install the product on the seashore, make sure that product is not directly exposed to sea
breeze by installing a protection wall.
2.
Consider that the salinity particles clinging to the external panels should be sufficiently washed out.
3.
Because the residual water at the bottom of the outdoor unit significantly promotes corrosion, make sure that the slope
does not disturb drainage.
-
Keep the floor level so that rain does not accumulate.
-
Be careful not to block the drain hole due to foreign substances.
4.
When the product is installed on the seashore, periodically clean it with water to remove the attached salinity.
5.
Make sure to install the product in a place that provides smooth water drainage. Especially, ensure that the base part
has good drainage.
6.
If the product is damaged during the installation or maintenance, make sure to repair it.
7.
When the product is to be shut down for a long period, such as off-peak hours, take appropriate measures like covering
the product.
8.
If the product is installed within 500m of the seashore, special anti-corrosion treatment is required.
❋
Please contact your local IGLU TECH representative for further details.
•
The protection wall should be constructed with a solid material that can block the sea breeze and the height
and width of the wall should be 1.5 times larger than the size of the outdoor unit. (You must secure more than
700mm of space between the protection wall and the outdoor unit for air circulation.
Содержание Inuit 6I
Страница 1: ...5 INSTALLATION MANUAL AIR TO WATER HEAT PUMP IGLU INUIT...
Страница 16: ...16 IGLU Inuit 6WTI indoor unit...
Страница 17: ...17 IGLU Inuit 9I outdoor unit IGLU Inuit 9I indoor unit...
Страница 18: ...18 IGLU Inuit 9WTI outdoor unit IGLU Inuit 9WTI indoor unit...
Страница 19: ...19 IGLU Inuit 12I IGLU Inuit 16I outdoor unit IGLU Inuit 12I IGLU Inuit indoor unit...
Страница 20: ...20 IGLU Inuit 12WTI IGLU Inuit 16WTI outdoor unit IGLU Inuit 12WTI IGLU Inuit 16WTI indoor unit...
Страница 27: ...27 SPACE REQUIREMENTS FOR OUTDOOR UNIT WHEN INSTALLING ONE OUTDOOR UNIT...
Страница 31: ...31 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 32: ...32 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 43: ...43...