66
2: Defrosting
3: Over-load
4: Discharge
5: Total
current
4: Down limit
15
IPM temp.
F
+/-
10s digit
1s digit
°C
long-1
Main Micom
version
Year (Dec)
Month (Hex)
Day (two
digits)
Day (One
digit)
-
long-1
and 1
Inverter Micom
version
Year (Dec)
Month (Hex)
Day (two
digits)
Day (One
digit)
-
long-1
and 2
EEPROM version
Year (Dec)
Month (Hex)
Day (two
digits)
Day (One
digit)
-
SETTING THE OPTION
1. Press and hold K2 to enter the option setting. (Only available when the operation is stopped)
- If you enter the option setting, the display will show the following.
- Seg1 and Seg2 will display the number for the selected option.
- Seg3 and Seg4 will display the number for the set value of the selected option.
2. If you have entered the option setting, you can shortly press the K1 switch to adjust the value of the Seg1, and Seg2
and select
the desired option.
Example)
3. If you have selected desired option, you can shortly press the K2 to switch to adjust the value of the Seg3, and Seg4
and change
the function for the selected option.Example:
4. After selecting the function for options, press and hold the K2 switch for 2 seconds. The edited value of the option will
be
saved when entire segments blink and tracking mode begins.
The edited option will not be saved if you do not end the option set as explained in the above instruction.
❋
While you are setting the option, you may press and hold the K1 button to reset the value to the previous setting.
❋
If you want to restore the setting to factory default, press and hold the K4 button while you are in the options setting
mode.
- If you press and hold the K4 button, the setting will be restored to factory default, but it doesn't mean that the restored
setting
is saved. Press and hold the K2 button. When the segments show that tracking mode is in progress, the setting will be
saved.
Содержание Inuit 6I
Страница 1: ...5 INSTALLATION MANUAL AIR TO WATER HEAT PUMP IGLU INUIT...
Страница 16: ...16 IGLU Inuit 6WTI indoor unit...
Страница 17: ...17 IGLU Inuit 9I outdoor unit IGLU Inuit 9I indoor unit...
Страница 18: ...18 IGLU Inuit 9WTI outdoor unit IGLU Inuit 9WTI indoor unit...
Страница 19: ...19 IGLU Inuit 12I IGLU Inuit 16I outdoor unit IGLU Inuit 12I IGLU Inuit indoor unit...
Страница 20: ...20 IGLU Inuit 12WTI IGLU Inuit 16WTI outdoor unit IGLU Inuit 12WTI IGLU Inuit 16WTI indoor unit...
Страница 27: ...27 SPACE REQUIREMENTS FOR OUTDOOR UNIT WHEN INSTALLING ONE OUTDOOR UNIT...
Страница 31: ...31 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 32: ...32 WHEN INSTALLING ONE INDOOR UNIT WITHOUT WATER TANK IGLU Inuit 6I IGLU Inuit 9I IGLU Inuit 12I IGLU Inuit 16I...
Страница 43: ...43...