ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
CAN in the ecomatmobile controller
Description of the CAN functions
73
Parameters of the function inputs
Name
Data type
Description
ID
WORD
Number of the data object identifier
Permissible values = 0...2 047
DLC
BYTE
Number of bytes to be transmitted from the array DATA
Permissible values = 0...8
DATA
ARRAY[0...7] OF
BYTES
The array contains a maximum of 8 data bytes
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
Parameters of the function outputs
Name
Data type Description
RESULT
BOOL
TRUE (only 1 cycle):
the function has accepted the transmit order