210
ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
More functions in the ecomatmobile controller
Counter functions for frequency and period measurement
10.1.7
Function INC_ENCODER
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0505
•
ExtendedController:
CR0200
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7200, CR7201, CR7505, CR7506
•
SmartController: CR2500, CR2501, CR2502
Function symbol:
INC_ENCODER
INIT
COUNTER
CHANNEL
UP
PRESET_VALUE
DOWN
PRESET
RESOLUTION
Description
INC_ENCODER handles up/down counter functions for the evaluation of encoders.
The function is designed as up/down counter. Two frequency inputs form the input pair which is
evaluated by means of the function. The following table shows the permissible limit frequencies and
the max. number of incremental encoders that can be connected:
Device
Limit frequency
max. number of encoders
ClassicController: CR0020, CR0505
10 kHz
4
ClassicController: CR0032
30 kHz
8
ExtendedController: CR0200
10 kHz
8
ExtendedController: CR0232
30 kHz
16
SmartController: CR2500, CR2501, CR2502
10 kHz
2
SafetyController: CR7020, CR7505
10 kHz
4
ExtendedSafetyController: CR7200
10 kHz
8
SafetyController: CR7021, CR7506
10 kHz
4
ExtendedSafetyController: CR7201
10 kHz
8
CabinetController: CR0301, CR0302, CR0303
10 kHz
2
PCB controller: CS0015
0.5 kHz
2
PDM360 smart: CR1071
1 kHz
2