ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
More functions in the ecomatmobile controller
Saving, reading and converting data in the memory
217
10.3.3
Function MEMCPY
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController: CR2500, CR2501, CR2502
•
PDM360 smart: CR1070, CR1071
Function symbol:
MEMCPY
DST
SRC
LEN
Description
MEMCPY enables writing and reading different types of data directly in the memory.
The function writes the contents of the address of SRC to the address DST. In doing so, as many
bytes as indicated under LEN are transmitted. So it is also possible to transmit exactly one byte of a
word file.
NOTE
The address must be determined by means of the function ADR and assigned to MEMCPY.
Parameters of the function inputs
Name
Data type Description
DST DWORD
Address
of
the target variables
SRC
DWORD
Address of the source variables
LEN
WORD
Number of data bytes
Содержание Ecomat 100 ecomatmobile SmartController CR2500