ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
More functions in the ecomatmobile controller
Software
reset
215
10.2 Software
reset
Using this function the control can be restarted via an order in the application program.
10.2.1
Function SOFTRESET
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController: CR2500, CR2501, CR2502
•
PDM360 smart: CR1070, CR1071
Function symbol:
SOFTRESET
ENABLE
Description
SOFTRESET leads to a complete reboot of the controller.
The function can for example be used in conjunction with CANopen if a node reset is to be carried out.
The behaviour of the controller after a SOFTRESET corresponds to that after switching the supply
voltage off and on.
NOTE
In case of active communication, the long reset period must be taken into account because otherwise
guarding errors will be signalled.
Parameters of the function inputs
Name
Data type Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed