ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
Programming and system resources
Limits of the SmartController
43
Function
Above average load
OUTPUT_CURRENT_CONTROL,
OCC_TASK
Simultaneous use of several current controllers
CAN interface
High baud rate (> 250 kbits) with a high bus load
PWM,
PWM1000
Many PWM channels at the same time. In particular the
channels as from 4 are much more time critical
INC_ENCODER
Many encoder channels at the same time
The functions listed above as examples trigger system interrupts. This means: Each activation
prolongs the cycle time of the application program.
The following indications should be seen as reference values:
7.2
Limits of the SmartController
Current controller
max. 1
If possible, do not use any other
performance-affecting functions
1 channel
Input frequency < 5 kHz
CYCLE,
PERIOD,
PERIOD_RATIO,
PHASE
4 channels
Input frequency < 1 kHz
INC_ENCODER
max. 2
If possible, do not use any other
performance-affecting functions!
ATTENTION
Risk that the controller works too slowly! Cycle time must not become too long!
►
When the application program is designed the above-mentioned recommendations must be
complied with and tested. If necessary, the cycle time must be optimised by restructuring the
software and the system set-up.