PWM in the ecomatmobile controller
Hydraulic control in PWM
197
9.3.9
Function NORM_HYDRAULIC
Contained in the library:
ifm_HYDRAULIC_16bitOS04_Vxxyyzz.LIB
ifm_HYDRAULIC_16bitOS05_Vxxyyzz.LIB
ifm_HYDRAULIC_32bit_Vxxyyzz.LIB
Available for the following devices:
ClassicController: CR0020, CR0505
ExtendedController: CR0200
SafetyController: CR7020, CR7021, CR7200,
CR7201, CR7505, CR7506
SmartController: CR2500, CR2501, CR2502
Available for the following devices:
ClassicController: CR0032
ExtendedController: CR0232
Function symbol:
NORM_HYDRAULIC
X
Y
XH
XL
YH
YL
X_OUT_OF_RANGE
Description
NORM_HYDRAULIC standardises input values with fixed limits to values with new limits.
Please note: This function corresponds to the 3S function NORM_DINT from the CoDeSys library
UTIL.Lib
.
The function standardises a value of type DINT within the limits of XH and XL to an output value within
the limits of YH and YL.
Due to rounding errors deviations from the standardised value of 1 may occur. If the limits (XH/XL or
YH/YL) are indicated in inversed form, standardisation is also inverted.
If X outside the limits XL…XH, the error message X_OUT_OF_RANGE = TRUE.
Typical characteristic curve of a
hydraulic valve:
The oil flow will not start before 20% of
the coil current has been reached.
At first the oil flow is not linear.