SmartController (CR2500, CR2502) V05
PWM in the ecomatmobile controller
Hydraulic control in PWM
191
Mode 1:
Characteristic curve linear with dead
band
Value for the dead band (DB) can be
set in % of 1000 increments
100 % = 1000 increments
DB = Dead_Band
Mode 2:
2-step linear characteristic curve with
dead band
Values can be configured to:
Dead band:
0…DB in % of 1000 increments
Step:
X = CPX in % of 1000 increments
Y= CPY in % of 1000 increments
100 % = 1000 increments
DB = Dead_Band
CPX = Change_Point_X
CPY = Change_Point_Y
Characteristic curve mode 3:
Curve rising (line is fixed)