228
ifm
System Manual
ecomat
mobile
SmartController (CR2500, CR2502) V05
More functions in the ecomatmobile controller
Data access and data check
10.4.4
Function SET_PASSWORD
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController: CR2500, CR2501, CR2502
•
PDM360 smart: CR1070, CR1071
Function symbol:
SET_PASSWORD
ENABLE
PASSWORD
Description
SET_PASSWORD sets a user password for the program and memory upload with the
DOWNLOADER.
If the password is activated, reading of the application program or the data memory with the software
tool DOWNLOADER is only possible if the correct password has been entered.
If an empty string (default condition) is assigned to the input PASSWORD, an upload of the application
software or of the data memory is possible at any time.
ATTENTION
Please note for CR250n, CR0301, CR0302 and CS0015:
The EEPROM memory module may be destroyed by the permanent use of this function!
►
Only carry out the function
once
during initialisation in the first program cycle!
Afterwards block the function again (ENABLE = "FALSE")!
NOTE
The password is reset when loading a new application program.