8 - TROUBLES - CAUSES - CURES
VIP80E-II
EN
8 - Pag. 3 / 4
8.3
TROUBLESHOOTING DURING BAR FEEDING
TROUBLES CAUSES SOLUTIONS
The pre-feeding and feeding
are stopped unexpectedly
Motor thermal switch tripped.
Reset the thermal circuit breakers
with the appropriate buttons.
The guides are not well adjusted.
Adjust the guides (see par. 5.3.).
The bar feeder - lathe guide is not
well adjusted.
Adjust the guide (par.5.4).
The bar hardly enters the lathe
spindle.
The bar feeder is not aligned with
the lathe.
Check and correct the alignment.
The carriage cannot complete
the pre-feeding stroke.
The bar is too long.
The maximum length cannot
exceed lathe spindle length.
The bar hardly enters the lathe
collet.
Excessive burr at the bar end.
Trim rag before feeding.