EN
8 - TROUBLES - CAUSES - CURES
SMART316
8 - Pag. 2 / 4
8.1 GENERAL
FAULTS
TROUBLE CAUSES CURES
No power
Check the electric connections
Open guard
Close the guard
Emergency systems on
Disconnect the emergency devices
The bar feeder will not start
Motor thermal switch tripped Reset the motor overload cut-out
with the special push-buttons.
The bar feeder has been reset
but the automatic cycle will not
start
No lathe signal
Check electric connection to the
lathe
The pneumatic devices will not
respond to controls
No air
Check the air system
The pre-feed and feed suddenly
stop
Motor thermal switch tripped Reset the motor overload cut-out
with the special push-buttons
8.2
BAR MAGAZINE - Faults
PROBLEMS CAUSES REMEDIES
During the loading operation
the bar cannot be inserted into
the magazine
The bar contrast strips are
too low
Adjust the position of the contrast
strips
The first bar in the magazine
fails to drop into the guides
The bar contrast strips are
incorrectly adjusted
Adjust the bar contrast strips (see
chapter 5.3.3).
Содержание SMART 316
Страница 4: ......
Страница 34: ...EN 4 HANDLING AND INSTALLATION SMART316 4 Pag 2 24 ...
Страница 56: ...EN 4 HANDLING AND INSTALLATION SMART316 4 Pag 24 24 ...
Страница 64: ...EN 5 ADJUSTMENTS AND SETTING UP SMART316 5 Pag 8 18 Replace the bar pusher supports ...
Страница 100: ...EN 7 BAR FEEDER MAINTENANCE SMART316 7 Pag 6 6 ...
Страница 104: ...EN 8 TROUBLES CAUSES CURES SMART316 8 Pag 4 4 ...
Страница 110: ...EN 9 PART REPLACEMENT SMART316 9 Pag 6 6 ...
Страница 114: ...EN 10 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SMART316 10 Pag 4 6 ...
Страница 138: ...EN 11 COLLETS SMART316 11 Pag 22 46 ...
Страница 156: ...EN 11 COLLETS SMART316 11 Pag 40 46 ...
Страница 163: ...12 LIST OF AFTER SALES CENTERS SMART316 EN 12 Pag 1 4 INDEX 12 1 LIST OF AFTER SALES CENTERS 2 ...
Страница 166: ...EN 12 LIST OF AFTER SALES CENTERS SMART316 12 Pag 4 4 ...