6 - USE AND OPERATION
SMART316
EN
6 - Pag. 13 / 20
6.4.2 Lubrication oil - Flow adjustment
Oil flow in the guides and bush-holder device is
automatically controlled during the feeder automatic
cycle.
The pump is started after the feeder has completed
bar change-over; it is stopped when the bar-pusher
approaches the centering device.
Oil flow should be adjusted according to bar
diameter and profile through the valve placed
upstream.