2 - TECHNICAL INFORMATION
SMART316
EN
2 - Pag. 13 / 20
Table 4. General technical specifications
SMART 316
Size of round bars
Ø min 3 mm
(1/8”)
Ø max 16 mm
(5/8”)
Size of hexagonal bars (size of wrench)
Min 3 mm
(1/8”)
Max 14 mm
(1” 9/16)
Min. bar length
1500 mm
Max. bar length
Mod. 32-3260
Mod. 40-4060
Magazine capacity (width)
nr.18 bars
Ø 10 mm (3/8”)
Max. bar weight
Mod. 32 - 9 Kg
Mod.40 - 11 Kg
Feeling speed (adjustable)
1000 mm/sec.
Return speed (adjustable)
1500 mm/sec.
Remnant length (standard version)
400 mm
Bar change time
(with a 3000 mm bar) Version 32
35 secs.
Voltage 230/400
Volt
Net frequency
50 Hz/ 60 Hz
Control voltage
24 Volt D.C.
Installed power
1.6 kW
Oil quantity
40 l
Max. air feed pressure
8 bar
Min. air feed pressure
6 bar
Average use of pneumatic energy (**)
3 NL/min
Dry weight
Mod.32 – 480 Kg.
Mod.40 – 560 Kg.
(**) Approximate value depending on the number of activation cycles.
Содержание SMART 316
Страница 4: ......
Страница 34: ...EN 4 HANDLING AND INSTALLATION SMART316 4 Pag 2 24 ...
Страница 56: ...EN 4 HANDLING AND INSTALLATION SMART316 4 Pag 24 24 ...
Страница 64: ...EN 5 ADJUSTMENTS AND SETTING UP SMART316 5 Pag 8 18 Replace the bar pusher supports ...
Страница 100: ...EN 7 BAR FEEDER MAINTENANCE SMART316 7 Pag 6 6 ...
Страница 104: ...EN 8 TROUBLES CAUSES CURES SMART316 8 Pag 4 4 ...
Страница 110: ...EN 9 PART REPLACEMENT SMART316 9 Pag 6 6 ...
Страница 114: ...EN 10 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SMART316 10 Pag 4 6 ...
Страница 138: ...EN 11 COLLETS SMART316 11 Pag 22 46 ...
Страница 156: ...EN 11 COLLETS SMART316 11 Pag 40 46 ...
Страница 163: ...12 LIST OF AFTER SALES CENTERS SMART316 EN 12 Pag 1 4 INDEX 12 1 LIST OF AFTER SALES CENTERS 2 ...
Страница 166: ...EN 12 LIST OF AFTER SALES CENTERS SMART316 12 Pag 4 4 ...