5 - ADJUSTMENTS AND SETTING-UP
SMART316
EN
5 - Pag. 13 / 18
5.3.2 Bar guide plates - Adjustment
Preliminary procedure
• Open the upper guard.
• Close the upper guide channel by pressing
on the keyboard (before the bar feeder
cover is opened) or the key on the electrovalve
for guide channel opening/closing.
Adjustment of the bar guide plates
• Loosen the handle "A", lift the plate and
tighten the handle "A"; repeat this operation on
all the plates.
• Prepare two bars of at least 1200 mm length.
• Feed two bars to the magazine, loosen the
handle "A" and drop the plates which will stop
against the bars.