Section 3: Programming IEI MiniMax 3 Installation/Programming Manual
Action Desired
Press
Details
Set Forced Door Time
45 # time # 0 # **
Time =forced door time, to nearest 10’s
seconds, entered as 30-990;
(
default=10 secs)
Reset System Defaults Only
40 # 00000 # 00000 # **
Does not delete users
Delete Entire Memory and Reset
System Defaults
46 # 00000 # 00000 # **
Deletes all memory including users
Program User – Code Only
50 # user type # user location
#
code
*repeat code *
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 - Emergency
Program User – Code AND Card
By Presenting Card
50 # user type # user location # code *
repeat code ** <present card>
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 - Emergency
Program User - Card Only
By Presenting Card
50 # user type # user location # **
<present card>
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 - Emergency
Program User – Card Only
Without Presenting Card
51 # user type # user location # card
PIN * card PIN *
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 - Emergency
For 26-bit Cards only.
The card PIN appears on the card
(Facility code must be entered first; see
32 # 4 # command)
Program User – Code OR Card
By Presenting Card
52 # user type # user location # code *
repeat code * <present card>
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 - Emergency
Page 44 of 48 Document #: 6055672, Rev 1.0 D1c