Section 3: Programming IEI MiniMax 3 Installation/Programming Manual
3.6.2 Programming a “Code Only” User
To program a “Code Only” use command 50. This user gains access by entering their code on the keypad. Refer to table 4 for details
on user types. Codes can be from 1 to 6 digit in length in any combination. The programming sequence is as follows:
Action
Command
Enter Program Mode
99 # master code *
Program User
50 # user type # user location # code * repeat code *
Exit Program Mode
*
3.6.3 Programming “Card Only” Users by Presentation
To program a “Card Only” user by presentation (by presenting the card to the reader) use command 50. This user type gains access by
presenting their card to the front end reader. Refer to table 4 for details on user types. The programming sequence is as follows:
Action
Command
Enter Program Mode
99 # master code *
Program User
50 # user type # user location # * * <present card>
Exit Program Mode
*
3.6.4 Programming 26-Bit “Card Only” Users without Presentation
To program a 26-Bit “Card Only” user without presentation (without presenting the card to the front end reader) use command 51.
Refer to table 4 for details on user types. This command is useful, if you want to program a card, but you don't have the physical card
with you.
When programming cards with this command, you must program the facility code, using command 32, parameter 2,
prior to programming users.
The programming sequence to program cards is as follows:
Action
Command
Enter Program Mode
99 # master code *
Program User
51 # user type # user location # card number * card
number *
Exit Program Mode
*
Page 32 of 48 Document #: 6055672, Rev 1.0 D1c
Note:
This programming command applies to Secured Series Front End Keypads only.
Note:
This programming command applies to Wiegand Front Ends only.